HHTAY-50-42, HHTAYZ-50-42(1-5/8”) RF Coaxial Cable
Construction Materials and Dimensions
Inner Conductor | Helix Corrugated Copper Tube | 17.30mm |
Dielectric | Foam PE | 43.20mm |
Outer Conductor | Annularly Corrugated Copper Tube | 46.50mm |
Jacket | Black PE or LSZH | 49.80mm |
Mechanical Characteristics
Single Bending Radius | Min. | 280mm |
Repeated Bending Radius | Min. | 500mm |
Number of Bends | Min. | 15 times |
Electrical Characteristics
Impedance | Nom. | 50±2Ω |
Velocity | Nom. | 88% |
Capacitance | Nom. | 76pF/m |
Dielectric Withstand Voltage | DC 1min | 15000V |
Insulation Resistance | DC 500V, 1min, Min. | 10000MΩ·km |
Jacket Spark Test Voltage (rms) | AC | 10000V |
DC Resistance, Inner Conductor | Max. | 1.50Ω/km |
DC Resistance, Outer Conductor | Max. | 0.52Ω/km |
VSWR
820~960MHz | Max. | 1.20 |
1700~2200MHz | Max. | 1.20 |
2300~2500MHz | Max. | 1.20 |
*Contact TD for your VSWR performance specification of your required frequency band. |
Environmental Characteristics
Storage Temperature | -30~+70℃ |
Installation Temperature | -25~+60℃ |
Operation Temperature | -30~+70℃ |
Attenuation
Frequency (MHz) | Attenuation (dB/100m,Max) |
800 | 2.60 |
900 | 2.78 |
1800 | 4.22 |
2000 | 4.51 |
2200 | 4.79 |
2400 | 5.06 |
2500 | 5.19 |
*Contact TD for your performance specification of your required frequency band. |
Since its establishment in 1999, TDII has been working with customers to create the best network cabling solutions to support their structured cabling systems. Our wealth of experience in the field of network infrastructure enables us to offer the complete services required in supporting and implementing your network cabling systems. Please contact us for more information about our network cabling services.